现代资讯现代实验室装备网
全国服务热线
400-100-9187、0731-84444840

Alkylphenol(AP) ELISA Kit烷基酚

 
品牌: 1048
单价: 面议
起订:
供货总量:
发货期限: 自买家付款之日起 天内发货
所在地: 全国
有效期至: 长期有效
最后更新: 1970-01-01 08:00
浏览次数: 158
 
公司基本资料信息
详细说明
Alkylphenol(AP) ELISA Kit烷基酚
 
AP ELISA Kit
• The monoclonal antibody binds exclusively with Alkylphenol(AP) , and does not cross-react with other surfactants or compounds of similar structure. 
• The detection range is between 5μg/L and 500μg/L. A simple concentration protocol based on solid phase extraction is available to determine much lower concentration. 
• With ease of handling, the total time for measurement is only 2.5 hours. 
• The kit, a 96-well microplate format, enables simultaneous measurement of multiple samples at more reasonable cost.
AP
AP is suspected as one of the endocrine disrupting chemicals in many countries. 
Octylphenol (n=8) and nonylphenol (n=9) are widely used as raw material of surfactants and anti-oxidants.
AP is generated by microbial decomposition of ethylene oxide chains in APE, which is widely used as nonionic surfactant. 
NPnEC, another decomposed product of APE, is also assumed as hormone mimicking chemicals.

AP Standard Curve 
 
 Samples containing AP within the dynamic range (5μg/L- 500μg/L) can be directly applied to assay after filtration. Samples with AP content below the range must be concentrated with solid phase extraction prior to the ensuing session. 
Coefficient of variation(CV) is generally under 10% throughout the dynamic range.


Pretreatment (Simplified Solid Phase Extraction) 
If an extraction and a concentration process is not necessary, add methanol to the filtrate to be a final DMSO concentration of 1% and methanol concentration of 10% (v/v). If not, prepare each sample by the extraction procedure.

[Example] 

1. Rinse a NEXUS SPE solid phase cartridge at 20ml/min. with dichloromethan (10mL) and methanol (5mL) then with distilled water (5mL). 
2. Pour sample liquid through the cartridge at 10mL/min. (up to about 1L) 
3. Wash the cartridge with distilled water (5mL). 
4. Wash the cartridge with 50% methanol (5mL). 
5. Dry the cartridge with vacuuming. 
6. Elute the analyte with dochloromethane (6mL) then evaporate the solvent with nitrogen gas. 
7. Dissolve the residue in 1%DMSO,10%methanol (1 to 2mL). 
8. Measure the sample with AP ELISA kit. 
Cross-reactivity Pattern 

Compound % reactivity
Nonylphenol (NP) 100
Octylphenol (OP) 96
Nonylphenol Ethoxylate (NPnEO)
NPnEO (n=1) 1.2
NPnEO (n=2) 2.1
NPnEO (n≒5) 3.2
NPnEO (n≒7.5) 4.5
NPnEO (n≒10) 4.9
Octylphenol Ethoxylate (OPnEO)
OPnEO (n≒10) 2.8
Nonylphenol Ethoxy Acetic acid (NPnEC)
NPnEC (n=1) 0.5
NPnEC (n=2) 1.5
NPnEC (n=3) 3.8
Anionic Surfactants
Linear Alkylbenzene Sulfonates (LAS) <0.1
Sodium Dodecyl Sulfate (SDS) <0.1
Alkylether Sulfate (AES) <0.1
Sodium Laurate (SORP) <0.1

Kit Format 
Kit Format Content Comment
Microplate 96 wells
& reagents Needs a microplate reader(450nm)
For multiple and simultaneous measurement

如有更多其它试剂产品需求与查询,请及时接洽:info@express-cn.com 或在我公司查询主页客户留言处(http://www.express-cn.com/expressgb/lyb.htm )留下您的查询内容,我们即会在当天为您作出回复。

伊普瑞斯科技有限公司
info@express-cn.com  
在线客服:QQ:1069267096
         MSN:liyuqiu1983@hotmail.com 
               cindylee-1981@hotmail.com 
联系人:杨先生
总机:010-60206266
传真:010-60206773
www.express-cn.com 

反对 0举报 0 收藏 0 评论 0
更多>本企业其它产品

Baidu
map