返回主站|会员中心|保存桌面|手机浏览
普通会员

伊普瑞斯科技有限公司

实验检测试剂,各种进口生化试剂,水体检测标准品等

新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
站内搜索
 
友情链接
  • 暂无链接
首页 > 供应产品 > Ethynylestradiol (EE2) ELISA Kit炔雌醇(EE2)试剂盒
Ethynylestradiol (EE2) ELISA Kit炔雌醇(EE2)试剂盒
浏览: 163
品牌: 1048
单价: 面议
最小起订量:
供货总量:
发货期限: 自买家付款之日起 天内发货
有效期至: 长期有效
最后更新: 1970-01-01 08:00
 
详细信息
Ethynylestradiol (EE2) ELISA Kit炔雌醇(EE2)试剂盒
 
EE2 ELISA Kit
• EE2 monoclonal antibody binds exclusively with EE2 and does not show cross-reaction with other hormones or chemicals with similar structures. 
• The quantitative analysis ranges from 0.05μg/L- 3μg/L(ppb), sensitive enough to detect EE2 in a specimen from river water or blood, etc. 
• With ease of handling, the total time for measurement is only 2.5 hours. 
• The ELISA measurement is highly reproducible; the coefficient of variation (CV) is generally under 10%. 
• The kit, a 96-well microplate format, enables simultaneous measurement of multiple samples at more reasonable cost.
EE2
Ethynylestradiol (EE2), one of main ingredients for contraceptive pill, is suspected as one of the endocrine disrupting chemicals. While GC-MS or LC-MS/MS are generally employed method for quantitative analysis, they require expensive instrumentation as well as complex and time-consuming extraction process with hazardous organic solvent. This test kit detects EE2 in environment or in vitro at a ppt level(ng/L) with the aid of solid phase extraction. 

EE2 Standard Curve
 
 Samples containing Ethynylestradiol(EE2) within the dynamic range (0.05μg/L- 3μg/L) can be directly applied to assay after filtration. Samples with Ethynylestradiol content below the range must be concentrated with solid phase extraction prior to the ensuing session. Coefficient of variation(CV) is generally under 10% throughout the dynamic range.

Pretreatment (Simplified Solid Phase Extraction)
Also see here
 
 Adjust the pH of the sample to 5.0 with 1M Acetic acid. Pour sample liquid through a C18 solid-phase cartridge/disk and elute EE2 with dichloromethane. 

Dry the sample with nitrogen gas, then adjust MeOH concentration at 10% for measurement.
• The specific procedure may vary in sample quality.

Cross-reactivity Pattern
Compound Reactivity (%)
Ethynylestradiol(EE2) 100.0
Estrone(E1) <0.2
2-methoxy E1 <0.2
17β-Estradiol(E2) <0.2
16-keto-E2 <0.2
E2-17-glucuronide <0.2
E2-3-glucuronide <0.2
E2-3-sulfate-17-glucuronide <0.2
Estriol(E3) <0.2
16-epi-E3 <0.2
E3-16-glucuronide <0.2

Kit Format
Kit Format Comment
Microplate 1 plate (96 wells)
& reagents Needs a microplate reader(450nm)
For multiple and simultaneous measurement

如有更多其它试剂产品需求与查询,请及时接洽:info@express-cn.com 或在我公司查询主页客户留言处(http://www.express-cn.com/expressgb/lyb.htm )留下您的查询内容,我们即会在当天为您作出回复。

伊普瑞斯科技有限公司
info@express-cn.com  
在线客服:QQ:1069267096
         MSN:liyuqiu1983@hotmail.com 
               cindylee-1981@hotmail.com 
联系人:杨先生
总机:010-60206266
传真:010-60206773
www.express-cn.com 

询价单
Baidu
map